50 research outputs found

    Analysis of HRT Images: Comparison of Reference Planes

    Get PDF
    PURPOSE. The values of Heidelberg Retinal Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) stereometric parameters depend on the reference plane (RP), the instability of which results in parameter variability. Identification of change depends on RP stability. This study was undertaken to evaluate the influence of various RPs on rim areas (RAs) in a longitudinal image series. METHODS. A longitudinal image series of 31 subjects with ocular hypertension who had reproducible visual field loss and 19 normal subjects was analyzed using five different RPs: the standard RP (HRT software version 3.1.2.0), two 320-m RPs (software ver. 3.1.2.0 and 1.7.0), a previously described experimental RP, and a new Moorfields RP. The Moorfields RP takes the standard RP at baseline and then is fixed relative to the reference ring for subsequent images. Classic methods, such as ophthalmoscopy and stereophotography, are widely used and are still important. These techniques involve the clinical examination of the ONH, to detect abnormalities associated with glaucoma, such as rim narrowing and notching, and recognition of large or asymmetric cup-to-disc ratios. However, these methods have limitations, since they rely on subjective judgment, and agreement between even expert observers on the presence of glaucoma or progressive change is not optimal. 5-10 Objective and reproducible measurements of the ONH surface topography are possible with scanning laser tomography. 11,12 Although scanning laser tomography appears to be reproducible, The HRT software applies two approaches to detection of change. The first is topographic change analysis, 14 in which the surface height in groups of pixels (super pixels) in follow-up images is compared with the surface height in the baseline image. Statistically significant change in surface height is color coded (red for relative depression, and green for relative elevation, compared to baseline). The second approach is to plot stereometric data, such as rim area (RA), over time. Currently, there is no statistical support in the software for this latter approach, but the potential value of quantifying RA over time to identify progression has been reported. Many different reference surfaces have been proposed

    In vivo measurements of prelamina and lamina cribrosa biomechanical properties in humans

    Get PDF
    Purpose: To develop and use a custom virtual fields method (VFM) to assess the biomechanical properties of human prelamina and lamina cribrosa (LC) in vivo. Methods: Clinical data of 20 healthy, 20 ocular hypertensive (OHT), 20 primary open-angle glaucoma, and 16 primary angle-closure glaucoma eyes were analyzed. For each eye, the intraocular pressure (IOP) and optical coherence tomography (OCT) images of the optic nerve head (ONH) were acquired at the normal state and after acute IOP elevation. The IOP-induced deformation of the ONH was obtained from the OCT volumes using a three-dimensional tracking algorithm and fed into the VFM to extract the biomechanical properties of the prelamina and the LC in vivo. Statistical measurements and P values from the Mann-Whitney-Wilcoxon tests were reported. Results: The average shear moduli of the prelamina and the LC were 64.2 ± 36.1 kPa and 73.1 ± 46.9 kPa, respectively. The shear moduli of the prelamina of healthy subjects were significantly lower than those of the OHT subjects. Comparisons between healthy and glaucoma subjects could not be made robustly due to a small sample size. Conclusions: We have developed a methodology to assess the biomechanical properties of human ONH tissues in vivo and provide preliminary comparisons in healthy and OHT subjects. Our proposed methodology may be of interest for glaucoma management

    Acute panuveitis with hypopyon in Crohn's disease secondary to medical therapy: a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A case report to highlight the association between rifabutin and hypopyon</p> <p>Methods</p> <p>A 56 year old male presented with a one day history of blurred vision in his right eye. He had an established diagnosis of Crohn's disease which was in remission following treatment with rifabutin and clarithromycin. A brisk anterior uveitis with hypopyon and a mild vitritis was detected in the right eye. The acute inflammatory episode resolved following treatment with topical corticosteroids and withdrawal of rifabutin.</p> <p>Results</p> <p>The presence of hypopyon is atypical in uveitis associated with inflammatory bowel disease. The association between rifabutin treatment and hypopyon uveitis is well recognised in Mycobacterium avium paratuberculosis. However, use of rifabutin in the management of Crohn's disease is controversial and not widely known to an ophthalmic readership.</p> <p>Conclusion</p> <p>This report highlights the importance of keeping abreast of novel therapeutic developments in systemic conditions likely to be encountered in ophthalmology.</p

    The association of female reproductive factors with glaucoma and related traits: A systematic review

    Get PDF
    TOPIC: This systematic review summarizes the existing evidence for the association between female reproductive factors (age at menarche, parity, oral contraceptive (OC) use, age at menopause, and postmenopausal hormone (PMH) use) and intraocular pressure (IOP) or open-angle glaucoma (OAG). CLINICAL RELEVANCE: Understanding the association between female reproductive factors and glaucoma may shed light on disease pathogenesis and aid clinical prediction and personalized treatment strategies. Importantly, some factors are modifiable which may lead to new therapies. METHODS: Two reviewers independently extracted articles in Medline, Embase, Cochrane Database of Systematic Reviews, and Cochrane Central Register of Controlled Trials databases to identify relevant studies. Eligibility criteria included studies with human subjects over 18 years of age; a measured exposure of at least one of the following: age at menarche, parity, OC use, age at menopause, PMH use; a measured outcome of either IOP or OAG; a cohort, case-control, cross-sectional or randomized-controlled trial design; and a reported measure of association including hazard, risk or odds ratio or mean difference with associated confidence intervals. RESULTS: We included a total of 27 studies. Substantial differences in study design, exposure and treatment levels, treatment duration and variable reporting precluded meaningful quantitative synthesis of the identified studies. Overall, relatively consistent associations between PMH use and lower IOP were identified. With respect to OAG, estrogen-only PMH use may be associated with lower OAG risk and this association may be modified by race. No significant associations were found with combined estrogen + progesterone PMH use. No strong associations between parity, or age at menarche and glaucoma were found, but a younger age at menopause was associated with increased glaucoma risk, and adverse associations were identified with longer duration of OC use, though no overall association with OC use was found. CONCLUSION: The association between PMH use and lower IOP/OAG risk is a potentially clinically relevant and modifiable risk factor and should be investigated further, although this needs to be interpreted in the context of a high risk of bias across included studies. There is a need for future research examining associations with IOP specifically, and how the relationship between genetic factors and OAG risk may be influenced by female reproductive factors

    Relationships between retinal layer thickness and brain volumes in the UK Biobank cohort

    Get PDF
    Background and purpose: Current methods to diagnose neurodegenerative diseases are costly and invasive. Retinal neuroanatomy may be a biomarker for more neurodegenerative processes and can be quantified in vivo using optical coherence tomography (OCT), which is inexpensive and noninvasive. We examined the association of neuroretinal morphology with brain MRI image-derived phenotypes (IDPs) in a large cohort of healthy older people. Methods: UK Biobank participants aged 40 to 69 years old underwent comprehensive examinations including ophthalmic and brain imaging assessments. Macular retinal nerve fibre layer (mRNFL), macular ganglion cell-inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and total macular thicknesses were obtained from OCT. Magnetic resonance imaging (MRI) IDPs assessed included total brain, grey matter, white matter and hippocampal volume. Multivariable linear regression models were used to evaluate associations between retinal layers thickness and brain MRI IDPs, adjusting for demographic factors and vascular risk factors. Results: A total of 2131 participants (mean age 55 years; 51% women) with both gradable OCT images and brain imaging assessments were included. In multivariable regression analysis, thinner mGCIPL, mGCC and total macular thickness were all significantly associated with smaller total brain (p < 0.001), grey matter and white matter volume (p < 0.01), and grey matter volume in the occipital pole (p < 0.05). Thinner mGCC and total macular thicknesses were associated with smaller hippocampal volume (p < 0.02). No association was found between mRNFL and the MRI IDPs. Conclusions: Markers of retinal neurodegeneration are associated with smaller brain volumes. Our findings suggest that retinal structure may be a biomarker providing information about important brain structure in healthy older adults

    Determinants of lamina cribrosa depth in healthy Asian eyes: the Singapore Epidemiology Eye Study

    Get PDF
    Aim To investigate the determinants of lamina cribrosa depth (LCD) in healthy eyes of Chinese and Indian Singaporean adults. Methods The optic nerve head (ONH) of the right eye of 1396 subjects (628 Chinese and 768 Indian subjects) was imaged with optical coherence tomography (OCT, Spectralis, Heidelberg, Germany). LCD was defined as the distance from the Bruch’s membrane opening (LCD-BMO) or the peripapillary sclera (LCD-PPS) reference plane to the laminar surface. A linear regression model was used to evaluate the relationship between the LCD and its determinants. Results Both LCDs were significantly different between the two races (LCD-BMO: 421.95 (95% CI 365.32 to 491.79) µm in Chinese vs 430.39 (367.46–509.81) µm in Indians, p=0.021; and LCD-PPS: 353.34 (300.98–421.45) µm in Chinese vs 376.76 (313.39–459.78) µm in Indians, p<0.001). In the multivariable regression analysis, the LCD-PPS of the whole cohort was independently associated with females (β=−31.93, p<0.001), Indians subjects (β=21.39, p=0.004) (Chinese as the reference), axial length (Axl) (β=−6.68, p=0.032), retinal nerve fibre layer thickness (RNFL) (β=0.71, p=0.019), choroidal thickness (ChT) (β=0.41, p<0.001), vertical cup disc ratio (VCDR) (β=24.42, p<0.001) and disc size (β=−60.75, p=0.001). For every 1 year older in age, the LCD-PPS was deeper on average by 1.95 µm in Chinese subjects (p=0.01) but there was no association in Indians subjects (p=0.851). Conclusions The LCD was influenced by age, gender, race, Axl, RNFL, ChT, VCDR and disc size. This normative LCD database may facilitate a more accurate assessment of ONH cupping using OCT in Asian populations

    Associations with photoreceptor thickness measures in the UK Biobank.

    Get PDF
    Spectral-domain OCT (SD-OCT) provides high resolution images enabling identification of individual retinal layers. We included 32,923 participants aged 40-69 years old from UK Biobank. Questionnaires, physical examination, and eye examination including SD-OCT imaging were performed. SD OCT measured photoreceptor layer thickness includes photoreceptor layer thickness: inner nuclear layer-retinal pigment epithelium (INL-RPE) and the specific sublayers of the photoreceptor: inner nuclear layer-external limiting membrane (INL-ELM); external limiting membrane-inner segment outer segment (ELM-ISOS); and inner segment outer segment-retinal pigment epithelium (ISOS-RPE). In multivariate regression models, the total average INL-RPE was observed to be thinner in older aged, females, Black ethnicity, smokers, participants with higher systolic blood pressure, more negative refractive error, lower IOPcc and lower corneal hysteresis. The overall INL-ELM, ELM-ISOS and ISOS-RPE thickness was significantly associated with sex and race. Total average of INL-ELM thickness was additionally associated with age and refractive error, while ELM-ISOS was additionally associated with age, smoking status, SBP and refractive error; and ISOS-RPE was additionally associated with smoking status, IOPcc and corneal hysteresis. Hence, we found novel associations of ethnicity, smoking, systolic blood pressure, refraction, IOPcc and corneal hysteresis with photoreceptor thickness

    Automated retinal image quality assessment on the UK Biobank dataset for epidemiological studies.

    Get PDF
    Morphological changes in the retinal vascular network are associated with future risk of many systemic and vascular diseases. However, uncertainty over the presence and nature of some of these associations exists. Analysis of data from large population based studies will help to resolve these uncertainties. The QUARTZ (QUantitative Analysis of Retinal vessel Topology and siZe) retinal image analysis system allows automated processing of large numbers of retinal images. However, an image quality assessment module is needed to achieve full automation. In this paper, we propose such an algorithm, which uses the segmented vessel map to determine the suitability of retinal images for use in the creation of vessel morphometric data suitable for epidemiological studies. This includes an effective 3-dimensional feature set and support vector machine classification. A random subset of 800 retinal images from UK Biobank (a large prospective study of 500,000 middle aged adults; where 68,151 underwent retinal imaging) was used to examine the performance of the image quality algorithm. The algorithm achieved a sensitivity of 95.33% and a specificity of 91.13% for the detection of inadequate images. The strong performance of this image quality algorithm will make rapid automated analysis of vascular morphometry feasible on the entire UK Biobank dataset (and other large retinal datasets), with minimal operator involvement, and at low cost
    corecore